Excavator Hydraulic Pump
-
Excavator Hydraulic Pump Parts
-
Travel Motor Assy
-
Excavator Swing Motor
-
Swing Gearbox
-
Excavator Control Valve
-
Travel Gearbox
-
Excavator Final Drive Parts
-
Excavator Center Joint
-
Hydraulic Gear Pump
-
Hydraulic Fan Motor
-
Excavator Spare Parts
-
Excavator Controller
-
Excavator Monitor
-
Excavator Relief Valve
-
Excavator Hydraulic Cylinder
-
Diesel Engine Assembly
-
krystal burgessAS ALWAYS, FAST AND FRIENDLY SERVICE.
-
James McBrideTransaction went smoothly, Seller was very helpful. Product arrived as promised, Very happy and will do business with them in future.
-
Dallas Skinnervery happy with all aspects of order. Communication was great from ordering to delivery
-
claudio vera garciathe product of very good quality. arrived in perfect condition and at the agreed time.
-
Daniela CzapskaI'm very satisfied! Transaction at the highest level. Item very well packed. Recommended the Seller
524-0924 5240924 Fan Pump Fan Cooler Pump 11R1435 Mh3250 Mh3260 E336 E340 E349GC E352 E349 E335

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCondition | New | Warrantty | 3month |
---|---|---|---|
Part Number | 524-0924 5240924 | Patr Name | Excavator Throttle Motor Gas Motor |
Voltage | 24V | Model | E336 E340 E349GC E352 E349 E335 |
Highlight | 5240924 Fan Pump,11R1435 Fan Pump,E335 Fan Pump |
524-0924 5240924 Fan Pump Fan Cooler Pump 11R1435 Mh3250 Mh3260 E336 E340 E349GC E352 E349 E335
erpillar SIS
336 Excavator YBN00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
336 Excavator JHD00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
336 Excavator GDY00001-UP (MACHINE) POWERED BY C9.3 Engine » 524-0924 PUMP GP-PISTON
336 Excavator DKS00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
336 Excavator SP900001-UP (MACHINE) POWERED BY C9.3 Engine » 524-0924 PUMP GP-PISTON
340 Excavator TYH00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
345 GC Excavator KEF00001-UP (MACHINE) POWERED BY C9.3 Engine » 524-0924 PUMP GP-PISTON
336 Excavator FEL00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
340 Excavator WDN00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
340 Excavator GMJ00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
340 Excavator TMK00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
340 Excavator SZT00001-UP (MACHINE) POWERED BY C9.3B Engine » 524-0924 PUMP GP-PISTON
349 Excavator LKG00001-UP (MACHINE) POWERED BY C13 Engine » 524-0924 PUMP GP-PISTON
352 Excavator MGR00001-UP (MACHINE) POWERED BY C13 Engine » 524-0924 PUMP GP-PISTON
349 Excavator RBY00001-UP (MACHINE) POWERED BY C13 Engine » 524-0924 PUMP GP-PISTON
Information:
Personal injury can result from escaping fluid under pressure.If a pressure indiion is shown on the indior, push the release valve in order to relieve pressure before removing any hose from the radiator.
Illustration 1 g02326293
(1) Water temperature regulator housing
(2) Water temperature regulators
Remove the water temperature regulators (2) from the engine.
Heat water in a pan until the temperature of the water is equal to the fully open temperature of the water temperature regulators. Refer to Specifiions, "Water Temperature Regulator" for the fully open temperature of the water temperature regulators. Stir the water in the pan. This action will distribute the temperature throughout the pan.
Hang the water temperature regulators in the pan of water. The water temperature regulators must be below the surface of the water. The water temperature regulators must be away from the sides and the bottom of the pan.
Keep the water at the correct temperature for 10 minutes.
After 10 minutes, remove the water temperature regulators. Immediately measure the opening of each water temperature regulator. Refer to Specifiions, "Water Temperature Regulator" for the minimum opening distance of the water temperature regulator at the fully open temperature. If the distance is less than the amount listed in the manual, replace the water temperature regulator.